| Analog Oscilloscopes SS-Series |
Specifications | |
 |
 |
 |
 |
| Parameter |
SS-7821A |
SS-7811A/ SS-7810A |
SS-7805A |
SS-7804A |
SS-7802A |
| Display |
| |
CRT |
6-inch
rectangular, internal graticule (8 x 10 div, with scale
illumination) - Japan made |
6-inch rectangular,
internal graticule (8 x 10 div) |
| Accelerating voltage |
Approx. 16
kV |
2 kV |
| Vertical deflection
system |
| |
Mode |
CH1, CH2,
CH3, ADD, ALT, CHOP |
CH1, CH2,
ADD, ALT, CHOP |
| Frequency bandwidth |
| 5 mV/div - 5 V/div |
DC - 200MHz |
DC - 100MHz |
DC - 50MHz |
DC - 40MHz |
DC - 20MHz |
| 2 mV/div |
DC - 50MHz |
DC - 50MHz |
DC - 20MHz |
DC - 20MHz |
DC - 10MHz |
| Sensitivity (CH1, CH2) |
2 mV/div -
5 V/div 11-step (1-2-5), 2 mV - 12.5 V/div (with
vernier) |
| Accuracy |
±2% |
| Bandwidth limiter |
20MHz |
Not
provided |
Rise time (Calculated from freq. bandwidth x
rise time = 0.35) |
1.75 nsec |
3.5 nsec |
7.0 nsec |
8.75 nsec |
17.5 nsec |
| Signal delay |
Available |
Not provided |
| Input coupling |
AC, DC, GND
(The cut-off freq. is 4Hz with AC coupl.) |
| Input RC: direct |
1 MW ±1.5% // 20 pF ±2 pF |
1 MW ±1.5% // 25 pF ±2 pF |
| Max. input |
1 MW input : 400 V (DC + AC peak), with
10:1 probe : 600 V (DC + AC peak) |
| Polarity switching |
Possible
only for CH2 |
| Probe sensor |
1:1, 1:10,
1:100 detection possible |
| Sensitivity (CH3) |
50 mV/div,
100 mV/div, 500 mV/div, ±2% |
- |
| Input coupling |
AC, DC |
- |
| Triggering |
| |
A triggering |
| Source |
VERT, CH1,
CH2, CH3, LINE |
VERT, CH1,
CH2, EXT, LINE |
| Coupling |
AC, DC,
HF-REJ, LF-REJ |
| Level |
| DC - 5MHz |
0.4 div |
0.4 div |
0.4 div |
0.4 div |
0.4 div |
| 5MHz - 10MHz |
0.4 div |
0.4 div |
1.0 div |
1.0 div |
1.0 div |
| 10MHz - 40MHz |
1.0 div |
1.0 div |
1.0 div |
1.0 div |
1.0 div (-20MHz) |
| 40MHz - 50MHz |
1.0 div |
1.0 div |
1.0 div |
- |
- |
| 50MHz - 100MHz |
1.0 div |
1.0 div |
- |
- |
- |
| 100MHz - 200MHz |
1.5 div |
- |
- |
- |
- |
| B triggering |
| Source |
CH1, CH2,
CH3, LINE |
- |
| Coupling |
AC, DC, HF-REJ, LF-REJ |
- |
| TV triggering |
NTSC,
PAL/SECAM, HDTV |
NTSC,
PAL/SECAM |
| Trigger mode |
TV-V (ODD,
EVEN, BOTH) line number selectable, TV-H |
| EXT
triggering input |
| |
Level |
| DC - 5MHz |
- |
80 mV |
80 mV |
80 mV |
| 5MHz - 20MHz |
- |
200 mV |
200 mV |
200 mV |
| 20MHz - 40MHz |
- |
- |
200 mV |
- |
| 20MHz - 50MHz |
- |
200 mV |
- |
- |
| Max. input voltage |
- |
1 MW: 400 V (DC + AC peak) |
| X-Y |
| |
X-axis |
CH1 |
| Sensitivity |
Same as
CH1 |
| Accuracy |
±3% |
| Bandwidth |
DC -
2MHz |
DC - 1MHz |
| Y-axis |
| Operating channel |
CH1, CH2,
CH3, ADD |
CH1,
CH2 |
| Horizontal deflection
system |
| |
Horizontal display |
A, ALT, B,
X-Y |
A,
X-Y |
| Mode |
AUTO, NORM,
SINGLE |
| A sweep time |
| Fastest range with mag. |
1 nsec/div |
2 nsec/div |
10 nsec/div |
10 nsec/div |
20 nsec/div |
| Slowest range |
500
msec/div |
| B sweep time |
Not provided |
| Fastest range with mag. |
1 nsec/div |
2 nsec/div |
- |
| Slowest range |
5
msec/div |
- |
| Accuracy A/B |
±2% |
| Delay |
Triggered
delay: CH1, CH2, CH3 Continuous delay: RUNS
AFTER |
- |
| Delay jitters |
1/20,000 |
- |
| Magnifier |
10
times |
| Hold-off time |
Variable
(up to sweep length or longer) |
| Auto setup |
V/H
position, V/H range, trigger |
Not
provided |
| |
Input channel |
CH1, CH2 |
- |
| Frequency response |
50Hz -
50MHz |
- |
| CH2 signal output |
DC - 100MHz |
DC - 100MHz |
DC - 20MHz |
DC - 20MHz |
DC - 10MHz |
| Calibrator |
Square-wave, 1kHz±0.1%, 0.6 Vp-p±1% |
| CRT read-out |
| |
Read-out |
Attenuator
range, ADD UNCAL, AC/DC/GND, vertical mode, CH2 polarity, A/B
sweep range, x10 MAG, UNCAL, horizontal display mode,
hold-off, trigger coupling, trigger source, trigger slope,
TV-field, TV-line, TV-system |
| Cursor measurement |
DV (voltage measurement), Dt (time measurement), 1/Dt (division calculation by Dt) |
| Frequency counter |
5-digit,
0.01% |
| |
Frequency range |
2Hz - 200MHz,
reciprocal |
2Hz - 100MHz,
reciprocal |
2Hz - 50MHz,
reciprocal |
2Hz - 40MHz,
reciprocal |
2Hz - 20MHz,
reciprocal |
| Save and recall |
| |
Power off set-up |
Panel
setting before switch is powered off |
| Back-up |
Battery
back-up (approx. 30,000 hr) |
| Power supply |
AC 90 V -
132 V/180 V - 250 V, 50Hz - 400Hz, max. 110 VA |
AC 100 V/110 V - 120
V/220 V/230 V - 240 V, 50Hz - 60Hz |
| Dimensions and
weight |
272W x 152H
x 390L mm, approx. 7.5 kg |
272W x 152H x 390L
mm, approx. 8.5 kg |
| Environment
conditions |
| |
Operating |
0°C -
+40°C, 90% RH (40°C) |
| Performance guaranteed |
+10°C -
+35°C |
| Standard
accessories |
Power cable
(x 1), probe (x2), fuse (x2), panel cover (x1), operation
manual (x 1) |
Power cable (x
1),probe (x 2), panel cover (x 1),operation manual (x
1) | | |
|